PICOWAVE by WAVELASER | Premium Pico Q Switch Laser Machine
Premium USFDA Q Switch Standard

PICOWAVE
by WAVELASER The Pinnacle of Q Switch Laser Engineering

Unlocking clinical perfection. Experience the next era of dermatological efficacy with the best q switch laser machine. Harnessing advanced pico-second pulse duration, PICOWAVE delivers unparalleled pigment crushing energy with absolute patient safety and minimum downtime.

700 ps Ultra-Short Pulse
6ns Active Q Switch
USFDA Engineered Security
PICOWAVE Premium Laser Machine
7-Joint Articulated Arm
Active Calibration
Ready State
1200 mJ Max
The Technology Paradigm Shift

Beyond Traditional Pulse Widths: The Pico Q Swich Revolution

Standard Nd:YAG Nanosecond lasers rely primarily on photothermal actions, heating up pigments and neighboring tissues. The revolutionary pico q swich mechanism shifts from a photothermal process to a purely photomechanical impact.

Traditional Q Switch Laser

Emits energy in nanoseconds. Large chunks of pigments are shattered through heating. This elevated thermal footprint increases the risk of post-inflammatory hyperpigmentation (PIH), requires cooling measures, and needs multiple sessions.

Advanced PICOWAVE Engine

Fires bursts in trillionths of a second (picoseconds). The sheer shockwave shatters targeted melanin into fine dust particle sizes without thermal side effects. Faster clearing, fewer treatments, and zero damage to the surrounding skin barrier.

Absolute Clinical Versatility

Dual-Wavelength Optical Precision

Equipped with two highly targeted clinical wavelengths to cover everything from dermal pigments to superficial epidermal lesions.

EPIDERMAL
532nm

Green Spectrum

Perfect for superficial brown pigmentations, freckles, solar lentigines, and targeting warm tattoo ink tones (red, orange, yellow).

DEEP DERMAL
1064nm

Near-Infrared

The ultimate workhorse for deep pigment clearing, Nevus of Ota, dark tattoo inks (black/dark blue) and high-level skin rejuvenation.

Clinical Evaluation

The Picowave Competitive Edge

Compare the technological gap between previous-generation systems and PICOWAVE, the state-of-the-art q switch laser platform.

Clinical Metric PICOWAVE by WAVELASER Traditional Q-Switch
Pulse Width Duration 700 Picoseconds 5 to 20 Nanoseconds
Target Fragmentation Method Photomechanical (Pure Shockwave) Photothermal (Intense Heating)
Averages Sessions Needed 3 to 4 Sessions 8 to 12 Sessions
Patient Comfort / Pain Level Minimal / No Topical Numbing Required Moderate to High / Requires Numbing
Thermal Side-Effects (PIH) Virtually Extinguished High Risk in Darker Fitzpatrick Scales
Energy Profiles & Control Constant Calibration / Micro-adjustable Manual / Higher risk of power spikes
Genesis Mode 3200 mJ Not Available
LP (Long Pulse) Mode 3000 mJ Not Available
Clinical Applications

Infinite Treatment Horizons

Empower your clinic to treat a wider range of indications with absolute precision and premium clinical outcomes.

Tattoo Removal

Shatters stubborn black, red, green, and multi-colored ink matrices with high peak power and minimum epidermal disruption.

Learn clinical protocol

Pigmentation Control

Target solar spots, freckles, melasma, and birthmarks with optimized photo-acoustic shockwaves safely.

Learn clinical protocol

Skin Rejuvenation

Induces Laser Induced Optical Breakdown (LIOB) in the dermis, igniting explosive neocollagenesis for fine-line correction.

Learn clinical protocol

Hollywood Peel

Also known as the Carbon Facial. Minimizes pore size, controls excessive sebum, and creates instant, camera-ready luminosity.

Learn clinical protocol
Engineering Specs

Technical Architecture

Clinical grade hardware designed to deliver absolute performance.

WAVELASER Orthogonal View
WAVELASER PICOWAVE Orthogonal
Arm Type Korean Optic
Cooling Dual Radiator
System Hardware
Heavy-duty 2 Lamps, 2 Rods professional architecture
Laser Type
Ultra-Premium Nd:YAG Active Picosecond Laser Engine
Wavelength Formats
1064nm, 532nm
Frequency & Spot Size
Frequency: 1-10 Hz adjustable
Spot Size: 2-10 mm continuously adjustable
Aiming Indicator
Red Diode laser (650nm) with customizable intensity
Cooling System
Closed-Loop Dual-Radiator Liquid to Air Heat Exchanger
Regulatory Certifications
Engineered to USFDA, CE, and ISO 13485 standards
Have Questions?

Clinical & Technical FAQs

Everything you need to know about integrating the PICOWAVE into your aesthetic practice.

PICOWAVE operates in picoseconds (one-trillionth of a second), which is significantly shorter than the nanosecond pulses of a traditional q switch laser. This prevents excessive thermal accumulation, breaking target pigments purely via micro-mechanical pressure. It requires significantly fewer sessions, handles stubborn ink colors, and vastly improves patient compliance and comfort.

Yes, the optical engineering behind PICOWAVE conforms to the stringent safety and power delivery metrics of a USFDA q switch laser machine. It utilizes dynamic self-calibrating optics and protective alarms to guarantee reliable power settings during all operations.

PICOWAVE features highly reliable, durable optical resonators. The optical lens array and articulating arm are designed to support more than 10,000,000 steady shots before any degradation. Replacement modules are reasonably priced and available through WAVELASER direct distribution networks.

The platform delivers two distinct highly-optimized wavelengths: 1064nm for deep dermal pigment clearance and dark inks, and 532nm for epidermal spots and warm tattoo ink colors.

Upgrade Your Practice to the
Gold Standard

Take the lead in your local medical aesthetic market. Stand out by offering treatment options backed by the absolute best q switch laser machine technology.

Scroll to Top